Company Name: |
Dexing Magnet Tech. Co., Ltd |
Contact Person: |
Jackie Tsui |
City: |
Xiamen |
Country: |
China
|
Local Time: |
|
E-mail: |
Premium
Membership Required (Join Free Today) |
|
Introduction: |
Dexing Magnet is located in the city of Xiamen, China which is a beautiful peninsula also an international seaport, with the factory in Jiangshu, Zhejiang China, was founded in 1985, the former identity is one military factory, researching and developing communication parts, this facility was later acquired by the Dexing Group in 1995. With manufacturing bases in both USA and Europe and applications engineering staffed facilities around the world, Dexing Magnet is perfectly positioned to provide local support to our customers for all of their magnetic needs. |
Business Type: |
Manufacturer |
Areas of
Interest: |
1. Electronics & Electricals/Electronic Instruments
|
|
|
|
Offers
From This Member (10) |
|
|
|
[Sell] micro dc magnetic induction push pull solenoid coil |
|
|
Solenoid Introduction of Solenoid: Solenoid is a kind of important tool for generating magnetic field, it has the advantages of simple structure, convenient use, the magnetic field in the axial direction after power on, and the magnetic field keeps the everlasting linear relationship with electric current, when length has a larger proportion with diameter, it has good homogeneity near the magnetic field center, and the larger the ratio is, the wider the uniform area will be, it is very suitable for the straight long sample magnetization. Multilayer solenoid can increase the magnetic field strength, the stronger magnetic field is, the stronger the power would be. Heat dissipation should be considered when long time use, even the protective action of electromagnetic force should be considered. Parameters of DXSL Series Solenoid: Model Length (mm) Outer Diameter (mm) Inner Diameter (mm) Max. magnetic field (Gs) Uniform area (mm) Evenness (ΔH/H) DXSL10-100 100 38 20 100 20 40 0.53% 2.5% DXSL10-500 100 85 20 500 15 30 0.62% 2.6% DXSL10-1000 100 190 20 1000 20 30 1.49% 3.37% DXSL20-100 200 73 50 100 20 40 0.14% 0.57% DXSL20-500 200 116 50 500 20 50 0.21% 1.36% DXSL20-1000 200 190 50 1000 20 60 0.3% 2.88% DXSL30-100 300 72 50 100 50 100 0.19% 0.87% DXSL30-500 300 115 50 500 50 80 0.21% 0.85% DXSL30-1000 300 180 50 1000 30 70 0.18% 1.03% DXSL30-2000 300 300 50 2000 30 80 0.29% 2.17% DXSL50-100 500 115 80 100 50 100 0.06% 0.27% DXSL50-500 500 155 80 500 50 120 0.36% 0.88% DXSL50-2000 500 320 80 2000 50 160 0.19% 2.81% DXSL70-100 700 135 100 100 70 120 0.05% 0.14% DXSL70-2000 700 340 100 2000 70 200 0.13% 1.02% DXSL100-100 1000 165 100 100 100 250 0.04% 0.24% DXSL100-500 1000 205 100 500 100 250 0.05% 0.31%
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] Pulse Magnetizer and Demagnetizer degausser |
|
|
Magnetizer and Demagnetizer Introduction DXMM series of magnetizer and demagnetizer are composed of high-pressure oil-immersed capacitor, silicon controlled rectifier (SCR) and control circuit. AC rise the power supply voltage through isolation transformer, then transform to DC through a rectifier to charge the capacitor. The high-voltage direct current energy is stored in the capacitor, reaches the setting voltage to shut off the charging circuit, finially, through control SCR, high-voltage energy discharge the magnetizing coil to generate a strong magnetic field to magnetize the magnet to saturation state. DXMM series of magnetizer or demagnetizer can be used for magnetizing or demagnetizing products made of permanent magnets, such as speakers, DC motor, DC fan, stepper motors, rubber magnets and magnetic toys, with excellent performance of low energy consumption, high efficiency, fast magnetization or demagnetization, can be matched with different magnetizing fixtures. Feature 1) low power consumption; 2) highe charge and discharge efficiency. 3) magnetizing or demagnetizing fixture design: high precision, durable. DXMM-1200 Series Item DXMM-12C20 DXMM-12C30 DXMM-12C40 Input power AC220V ± 10% AC380V ± 10% AC380V ± 10% Input current 40A Charging voltage DC 200V-1200V Capacitance 2000uF 3000uF 4000uF Stored energy 1440J 1296J 2880J Output current 15KA Magnetizing interval 1.0 sec/time 2.0 sec/time 3.0 sec/time DXMM-2500 Series Item DXMM-25C10 DXMM-25C16 DXMM-25C20 Input power AC220V ± 10% AC380V ± 10% AC380V ± 10% Input current 40A Charging voltage DC 200V-2500V Capacitance 1000uF 1600uF 2000uF Stored energy 3125J 5000J 6250J Output current 30KA Magnetizing interval 2.0 sec/time 3.0 sec/time 3.0 sec/time More models, please visit our website.
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] Hall Effect System electromagnetic effect |
|
|
1. Function Measurement of Hall Effect and magnetic resistance, curves of I-V and R-T. Parameters to be measured: Hall Effect- sheet resistance, resistivity, Hall coefficient, conductivity type, Hall mobility, carrier concentration; Magnetic resistance effect: I-V curve: I-V curves at different temperature and magnetic field. R-T curve: Under different magnetic field, the curves for resistance changes with temperature. 2. Material to be measured: Semiconductor materials: Si, Ge, AlGaAs, GaAs, GaN, HgCdTe, CdTe, etc. Low impedance materials: metals, transparent oxides, weak magnetic semiconductor materials, TMR materials. Ferrite. 3. Technical Details: Magnetic field range: 1.7T (pole spacing 22mm) 1.1T (pole spacing 40mm) Resistance range: 1mΩ ~ 10MΩ Carrier concentration: 106 ~ 1019cm3 Migration rate: 100 ~ 105cm2/Vs Systematic measurement errors: <2% Measurents from room temperaure (300K) to 77K (LN2). 4. Features: 1). Real-time closed-loop control system using magnetic fields, can provide high stability of the magnetic field, the user can freely change the magnetic field required for testing; 2). Test samples in the low-temperature nitrogen atmosphere, the sample temperature and the temperature of the gas exchange is the same, there is no heat transfer due to measurement errors caused by temperature and temperature gradient effects within the sample; 3). Quick and easy replacement of the sample to improve the testing efficiency; 4). Automated testing software, can achieve a constant magnetic field variable-temperature automatic testing, automatic constant temperature, magnetic field test, or variable-temperature magnetic field of automated testing, variable-temperature magnetic field of automated testing is a more complete and comprehensive testing; 5. Electrode contacts: 4 or 6 6. Temperature environment: The standard variable-temperature system with no option but to carry out measurements at room temperature. Liquid nitrogen Dewar or refrigerator available options, the line of low temperature test. 7. Magnetic field: The use of electromagnets can produce 0 ~ 2T variable magnetic field. 8. Sample max. voltage: 200V 9. Current range of sample: ±10nA to±1A; 10. Resistance range: 1mΩ ~ 10MΩ |
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] DXMC25-100 generator field coil helmholtz magnetic induction coil |
|
|
DXMC25-100 One Axis DC Helmholtz Coil Introduction: Using two same coils with equal radius and turns,arrange them to be coaxial and let their distance be equal to the radius of the coil,this called Helmholtz coil. DXMC25-100 one axis Helmholtz coil is consist of two coils with average radius 250mm, to generate 100Gs uniform magnetic field. Technical parameters: 1. Center magnetic field Hmax : 100Gs 2. Magnetic field center evenness(^H/H) : 0.1% 3. Even magnetic space : D83 X 83 mm3 4. Average diameter : 500mm 5. Weight : 10kg 6. DC resistance : 4 Ohm 7. Power of power source: 600W 8. Continious working time (200Gs) : 30min Application: 1. to generate standard magnetic field 2. calibration for Hall probes and various magnetometers 3. compensation for earth magnetic field 4. judgement for magnetic shielding effect 5. measurement and removement for space radiation magnetic field 6. for magnetic properties 7. study for biomagnetism Note: Magnetic field intensity: the value of the magnetic field in the magnetic field center, when power is maximum Uniform area: the relatively homogeneous magnetic field space surrounding magnetic field center, or the required magnetic field for users’experiments Space uniformity: the magnetic deviation degree in uniform area Stability: the degree of change when the magnetic field working over a period of time. Working time: the longest using time Work period: the interval time between continuous work for more than two times |
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] 3 Axis Helmholtz Coil magnetic field induction coil |
|
|
Helmholtz Coil Using two same coils with equal radius and turns,arrange them to be coaxial and let their distance be equal to the radius of the coil,this called Helmholtz coil. It can be used to generate magnetic field from extremely weak magnetic to hundreds of Gauss. Specifications: Model Shape Average radius (cm) Center magnetic field(Gs) Power (W) Even magnetic field space(mm3) Magnetic field center evevness ^H/H DXHC75-5 square 75 5 500 375×375×375 1×10-2 250×250×250 1×10-3 DXHC75-2 square 75 2 300 60×60×60 1×10-4 DXHC60-10 square 60 10 700 200×200×200 1×10-3 48×48×48 1×10-4 DXHC60-2 square 60 2 200 300×300×300 1×10-2 DXHC50-20 square 50 20 800 250×250×250 1×10-2 DXHC50-2 square 50 2 100 40×40×40 1×10-4 DXHC40-50 square 40 50 1500 200×200×200 1×10-2 DXHC40-10 square 40 10 400 133×133×133 1×10-3 DXHC40-2 square 40 2 100 32×32×32 1×10-4 DXMC30-300 round 30 300 5500 150×150×150 1×10-2 DXMC30-50 round 30 50 1000 24×24×24 1×10-4 DXHC30-10 round 30 10 200 150×150×150 1×10-2 DXHC30-2 round 30 2 50 100×100×100 1×10-3 DXMC25-1000 round 25 1000 8000 Ø125×125 1×10-2 DXMC25-500 round 25 500 4000 Ø83×83 1×10-3 DXMC25-50 round 25 50 500 Ø20×20 1×10-4 DXMC25-10 round 25 10 100 Ø125×125 1×10-2 DXMC25-2 round 25 2 20 Ø83×83 1×10-3 DXMC20-500 round 20 500 2500 Ø100×100 1×10-2 DXMC20-50 round 20 50 500 Ø67×67 1×10-3 DXMC20-10 round 20 10 100 Ø16×16 1×10-4 DXMC20-5 round 20 5 50 Ø100×100 1×10-2 DXMC20-2 round 20 2 30 Ø67×67 1×10-3 DXMC15-300 round 15 300 1000 Ø75×75 1×10-2 DXMC15-100 round 15 100 400 Ø12×12 1×10-4 DXMC15-10 round 15 10 50 Ø50×50 1×10-3 DXMC10-200 round 10 200 400 Ø50×50 1×10-2 DXMC10-50 round 10 50 100 Ø8×8 1×10-4 DXMC10-10 round 10 10 30 Ø50×50 1×10-2 DXMC7-100 round 7 100 100 Ø35×35 1×10-2 DXMC7-50 round 7 50 50 Ø23×23 1×10-3 DXMC7-10 round 7 10 20 Ø6×6 1×10-4
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] Strong magnetic field powerful electromagnet electric magnet |
|
|
DXSG Series Fixed Air Gap Electromagnet: Double-yoke fixed air gap electromagnets have the best rigidity, they can installed vertically or at certain angle, and the magnetic field is horizontal. This kind of electromagnets are suitable for applications of the situation that requires strict magnetic field gap changes and high magnetic field evenness, such as NMR test, vibration sample magnetometer and so on. The magnetic air gap can be changed through replacing magnetic pole-head. DXSG Double-Yoke Fixed Air Gap Electromagnet Model Pole Diameter (mm) Air Gap Range (mm) Polar Face (mm) Maximum Magnetic Field (T) Power (KW) DXSG-100 Ø100 10 Ø50 2.0(10mm air gap) 1.6 DXSG-130 Ø130 30 Ø60 1.7(30mm air gap) 3.0 DXSG-200 Ø200 30 Ø100 1.7(30mm air gap) 5.0 DXSG-300 Ø300 30 Ø80 2.7(30mm air gap) 20.0 DXSG-380 Ø380 25 Ø150 2.95(25mm air gap) 22.0 DXSG-550 Ø550 50 Ø140 3.5(50mm air gap) 50.0 More models, please visit our website or contact us.
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] Adjustable Air Gap Powerful Electromagnet |
|
|
DXSB Double-Yoke Double-Tuning Adjustable Air Gap Electromagnet Introduction of DXSB Double-Yoke Double-Tuning Adjustable Air Gap Electromagnet: Designed with best rigidity, magnetic circuit symmetry. The electromagnet can be fixed upright, down or to certain angle. This kind of electromagnet can be used in many kinds of magnetic testing. For example: magnetic material testing, vibration sample magnetometer, magnetic susceptibility testing, Hall Effect research, Torsion magnetometer, magneto-optical effect test, hysteresis flex test and MRI test, etc. Model Pole Diameter (mm) Air Gap Range (mm) Pole Face (mm) Magnetic field index Power Air Gap (mm) Maxium Magnetic Field(T) DXSB-50 D50 0-80 D50 10 1.0 0.3KW DXSB-100 D100 0-80 D60 10 2.0 1.6KW D100 20 1.15 DXSB-130 D130 0-100 D60 10 2.55 3.0KW D120 30 1.3 DXSB-175 D175 0-120 D60 10 2.65 5.0KW D100 50 1.4 D150 100 0.7 DXSB-200 D200 0-140 D60 10 2.8 8.0KW D80 30 1.8 D140 70 1.0 DXSB-250 D250 0-140 D60 10 3.2 12.0KW D80 40 2.1 D120 80 1.3 DXSB-280 D280 0-150 D70 10 3.45 16.0KW D120 70 1.7 DXSB-380 D380 0-180 D100 40 2.4 20.0KW
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] DX-2012H DC Hysteresis Graph Test System for Hard Magnet |
|
|
DX-2012H DC Hysteresis Graph Test System Automatic measurement of the demagnetization curve of permanent magnetic material such as ferrite, AlNiCo, NdFeB, SmCo, etc. Accurate measurement of the magnetic characteristic parameters of remanence Br, coercive force HcB, intrinsic coercive force HcJ and maximum magnetic energy product (BH)max. Windows measurement software applied simply. The product conforms to China National Standards GB/T 3217-92, GB 11209-89 and international standard IEC 404-5. Adopt ATS structure, users can customize different configuration as required: According to the intrinsic and size of measured sample to decide the electromagnetic size and corresponding testing power supply; Select different measuring coil and probe according to the option of measuring method. Decide to whether choosing fixture in accordance with sample shape. Decide to whether selecting heating installation or not according to the test requirement. General Features of DC Hysteresis Graph (DX-2012H) Automatic measurement on saturation hysteresis loop and magnetic characteristic parameters of generally permanent-magnet material such as Ferrite, Rubber & Plastic Magnet and AlNiCo, etc.: Js, Br, HcB, HcJ, (BH)max and µrec. Automatic measurement on demagnetization curve and magnetic characteristic parameters of rare earth permanent-magnet materials such as NdFeB and SmCo, etc. at the second quadrant: Br, HcB, HcJ, Hk(H90) and (BH)max. Test sample shapes: circular ring, round cake, square, tile and other irregular shapes. Adopt B coil + fluxmeter to measure magnetic induction, zero shift of integrator can be self-corrected through software. Adopt J coil + fluxmeter to measure magnetical polarization, remnant coil area of J coil can be automatically compensated through software. Magnetic field intensity can be measured with Hall magnetometer, nonlinear error of hall probe can be corrected through software, within 0 ~ 2.4T range, nonlinear error can be controlled within±0.2%. Adopt H coil + fluxmeter to measure magnetic field intensity, Hall magnetometer only used to indicate zero point of magnetic field so as to thoroughly eliminate nonlinear error of hall probe. Optimal range of field voltage, fluxmeter and magnetometer can be automatically set up. Magnetization, testing and demagnetization of general permanent magnetic sample completed at one time, time set up 20 seconds ~ 60 seconds. Rare earth permanent magnetic samples need saturation magnetizing before testing, testing time 60 seconds ~ 120 seconds. The sample after tested is in demagnetization or magnetizing status, freely selected by users. Select heating head and temperature controller to detect magnetic characteristics of Ferrite, AlNiCo and rare earth material under high temperature (maximal 220°C). Select shoe jig for direct measurement on magnetic shoe. Technical Data of DC Hysteresis Graph (DX-2012H) System Specifications Test AlNiCo standard sample, measuring error on entire magnetic hysteresis cycle estimated: B: 1%, H: 1% Parameters measured Br(%) HcB(%) HcJ (%) (BH)max(%) Uncertainty (k=2) 1 1 1 2 Repeatability (constant temperature) ± 0.3 ± 0.3 ± 0.3 ±1 Instrument Specifications TPS-2000H Test Power Supply DCT150 Electromagnet Output Voltage: 0 ~±100V Output Current:±20A (maximum value) Stability: superior to 0.05% Stability: superior to 0.05% Head Diameter: 150mm shrink to 80mm Head Spacing: 0 ~ 50mm (continual adjustable) Maximal Magnetic Field: 2.4T (head spacing 10mm, coil current 30A) LZ-210B Fluxmeter DCT200 Electromagnet Range: 2.5, 5, 10, 20mWb Full Range Precision: 0.5% Zero Shift: 2µWb /30 seconds (2.5mWb) Head Diameter: 200mm shrink to 120mm Head Spacing: 0 ~ 50mm (continual adjustable) Maximal Magnetic Field: 2.4T (head spacing 10mm, coil current 40A) LZ-210H Magnetometer DCT250 Electromagnet Range: 0.5, 1, 1.5, 3T Full Range Precision: 0.5% Non-Linearity:±0.2% (software correction) Head Diameter: 250mm shrink to 150mm Head Spacing: 0 ~ 50mm (cont |
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] DX-160 Full digital high precision gaussmeter teslameter magnetic tester |
|
|
DX-160 Full-digital high-precision gauss meter DX-160 Full-digital high-precision gaussmeter/teslameter is designed for high-test precision, high-resolution magnetic field test applications. It provides a wide-range measurement from DC to up to 50kHz AC magnetic field measurement. It also has functions of auto-zeroing and auto-range. Maximum value, minimum value, peak and valley is selectable at hold mode. This instrument can measure and display 6 parameters simultaneously. Units of measure optional Gauss, Tesla, A / M or Oe. This instrument also provides RS232 interface for communications with PC. It is designed and manufactured in accordance with ISO-9001 standard. With the functions of bright VGA color graphics, full menu operation, 5 ¾-bit readings, high-resolution 1 / 600000, it makes you convenient to observe 0.0001mT weak changes in the high magnetic field measurements. It is able to measure maximum at 30KG (3T).It has a large-capacity data storage and you can review the historical-data according to storage time and it can upload data to PC. Products are mainly sold to large institutes, universities and research departments of large factories. Optional: Remote Control System, Gauss Meter Professional mapping software, Industrial control output components, zero gauss chamber Features 5 ¾-bit resolution on VGA color panel Basic DC accuracy: ±0.20% of reading Time and display brightness configurable Basic resolution: 0.00001 mT Maximum/minimum/peak/valley holding and interface locking Threshold setting and alarming Data-storage(auto/manual)/historical-data reviewing Auto-zero, automatic/manual range Probe Auto Calibration / Auto Memory operation mode RS-232C interface / data output Display units optional Gauss, Tesla, A / M or Oe Zero setting / relative measurement mode Communication baud rate adjustment / working temperature display Matching Zero Gauss Chamber/Gauss Meter Professional mapping software dozens of optional basic probe (standard 0.50mm ultra-thin probe) Model-160 Specifications Range 1mT = 10Gs *(0.1mG-30Gs)/(1mGs-300Gs)/(0.01Gs-3000Gs)/(0.1Gs-30KG) Resolution 0.1mGs(0.01uT) Accuracy (display value) DC Reading of 0.20% ± 0.005% range AC ±1% of reading Frequency range DC mode Dc to 50Hz AC mode 2Hz to50kHz Analog Output Output Voltage ±3V F.S. Connectors Standard BNC Additional effects Temperature Coefficient ±(0.02% ±1 count)/ ºC Temperature range Working temperature 0ºC to +50ºC Storage temperature -20ºC to +60ºC Panel Display 3.5 inch VGA, 320 x 240 Pixel Communication Interface RS-232 Standard 9-pin D-type connectors Supply power Voltage: 200/240v Frequency: 50-60 Hz
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
[Sell] portable gauss meter |
|
|
DX-102 Gaussmeter is a DSP designed hand-held Gauss meter, based on the latest technology of hall-effect measuring instruments for measurement of the magnetic field strength. It has a maximum range up to 0 - ± 30mT, 0 - ± 300mT, 0 - ± 3000mT, and a minimum basic accuracy up to 1.0%, as well as powerful test and display function, easy to carry. It is the best on-site surface magnetic field measuring instrument. Application: Measurement of surface magnetic field, DC coil magnetic field, Air-gap magetic field of DC electromagnet. Features: 1. Onekey zero adjustment automatically 2. Measuring range change automatically 3. Lock the change of peak and relatative mode. 4. Beautiful appearance, clear dot matrix frequency display 5. Calibrated by standard magnetic field. 6. Low carbon saving energy due to low-voltage circuit design. 7. High accuracy and linearity using imported GaAs-hall sensor 8. Power off automatically 9. Peak holding 10. Polarity identifying Technical Parameters: Power Supply 6V battery Measuring Range 0-±30.0mT,0-±300mT,0-±3000mT three gears,gear shifting automatically Accuracy More than 1.0% (full scale) Resolution 0.1 mT(1Gs) Working Condition Temp.: 0~50ºC, humidity:35~80% Normal Probe 0.65mm(D)×3.5mm(W) Senstive area:0.5x0.5mm 1Gs Thin Probe 0.32mm(D)×1.2mm(W) Senstive area:0.25x0.25mm 1Gs Dimension 170mm×90mm×40m Weight 450g
|
|
» Electronics & Electricals/Electronic Instruments |
|
|
|
|
|
Pages: 1
|
|
|
|